top of page
Search

Steady State Conduction: Equations, Resistances, Examples

24 hours ago
7 min read

Copper bar between hot and cold ends

Steady state conduction is heat flow through a solid when the temperature at every point has stopped changing with time. Heat still moves, but the temperature field holds still. That single condition turns a hard time-dependent problem into algebra for simple shapes. Our Engineering Toolkit combines conduction, convection and radiation models with a built-in property database, so you can run these calculations without a paid license.



TL;DR

 

  • Steady state means temperature depends on position but not on time; transient analysis seeks temperature as a function of time.

  • With constant conductivity and no heat generation, the governing equation reduces to Laplace’s equation, ∇²T = 0.

  • For walls, tubes and spheres, treat each layer as a thermal resistance and use q = ΔT/R.

  • A well-posed problem needs geometry, conductivity, generation and enough boundary data. No initial condition is required.

  • Use a one-dimensional hand calculation first, then move to a multidimensional model when heat clearly spreads sideways.

 

Table of Contents

 

 

What steady state conduction means

 

Conduction is heat transfer through a material without bulk motion. In the steady case the temperature field does not change with time, though it can vary with position and heat can continue to flow, as the Princeton Heat and Mass Transfer notes put it.

 

A copper bar with one end held hot and the other cold shows this. Once the bar settles, each cross-section sits at a fixed temperature, and the same heat rate enters one end and leaves the other. Nothing is being stored.

 

The contrast is transient conduction, where temperatures change with time and the solution needs an initial temperature distribution. According to course material from GEC Gudlavalleru, steady problems do not need that initial condition. If you are unsure which case you have, our guide on transient heat conduction covers the Biot and Fourier number checks.


Steady and transient conduction compared over time

How to tell whether steady state applies

 

Thermal diffusivity, α = k/(ρc), compares conduction with the material’s ability to store energy. The Wiley Heat Conduction Fundamentals excerpt explains that it, not conductivity alone, sets how fast a disturbance propagates. Low diffusivity and thick sections mean long settling times. A heat sink under constant power for hours is steady for practical purposes. A part that sees a short power pulse is not.

 

The governing equation

 

For a solid, the energy balance is ∇·(k∇T) + q̇ = ρc ∂T/∂t, where q̇ is volumetric heat generation. This form appears in Lienhard’s A Heat Transfer Textbook. At steady state the right side is zero:

 

  • General steady form: ∇·(k∇T) + q̇ = 0

  • Constant isotropic k, with generation: ∇²T + q̇/k = 0 (Poisson’s equation)

  • Constant isotropic k, no generation: ∇²T = 0 (Laplace’s equation)

 

The Wiley excerpt derives these from Fourier’s law and conservation of energy. The constant-k assumption is a convenience, not a law. Conductivity often changes with temperature, and numerical methods handle that, which is why textbooks such as Nellis and Klein’s include temperature-dependent properties in their numerical chapters.

 

One-dimensional solutions by geometry

 

When heat flows mainly in one direction, each geometry has a closed-form solution. The expressions below follow the Malla Reddy College heat transfer notes, for constant k and no generation.

 

Geometry

Resistance

Temperature profile

Plane wall, thickness L, area A

R = L/(kA)

Linear in x

Hollow cylinder, radii r₁, r₂, length L

R = ln(r₂/r₁)/(2πkL)

Logarithmic in r

Spherical shell

R = (1/r₁ − 1/r₂)/(4πk)

Constant plus a 1/r term

Convective surface

R = 1/(hA)

Temperature drop in the fluid film

In every case the heat rate is q = ΔT/R once boundary temperatures and dimensions are known. For a plane wall this reads q = kA(T₁ − T₂)/L.

 

The convection resistance comes from Newton’s law of cooling, and the same notes give it as 1/(hA).

 

Worked example: a furnace-style wall

 

Take a 0.2 m thick wall with k = 1.0 W/m·K and area 5 m². The inside face is held at 400 °C and the outside face at 100 °C.

 

  1. Resistance: R = 0.2 / (1.0 × 5) = 0.04 K/W.

  2. Heat rate: q = (400 − 100) / 0.04 = 7,500 W.

  3. Temperature at the midplane: because the profile is linear, it is 250 °C.

 

Now replace the fixed outside temperature with convection to 25 °C air at h = 10 W/m²·K. The convective resistance is 1/(10 × 5) = 0.02 K/W. Total resistance is 0.06 K/W, so q = (400 − 25) / 0.06 = 6,250 W. The outer surface temperature is 25 + 6,250 × 0.02 = 150 °C. The resistances add in series, and the air film takes a third of the total drop. That is why outer-surface conditions often matter as much as the wall itself.

 

Layers and composite walls

 

For stacked layers, add the resistances in series. The same heat rate passes through each layer, so each layer’s temperature drop equals q times its resistance. Our heat conduction calculation guide works through more formulas and examples, including cylinders.

 

Boundary conditions and what you must specify

 

The equation alone has many solutions. You need the geometry, conductivity (including any direction or temperature dependence), internal generation, and enough boundary data to fix a unique answer, as Lienhard describes. Common choices, listed in the Princeton notes:

 

  • Prescribed temperature (first kind): a surface held at a known value.

  • Prescribed heat flux (second kind): includes an insulated face, where flux is zero.

  • Convection (third kind): flux equals h(Ts − T∞), with h and ambient temperature given.

  • Interfaces: temperature and normal heat flux are continuous across the contact.

 

The naming of kinds follows the GEC Gudlavalleru material. In finite-element language, the University of Florida notes treat specified temperature as essential and prescribed flux as natural, with convection as a mixed condition because it depends on the unknown surface temperature.

 

Picking the right condition is where most models go wrong. A fixed temperature on a surface that really cools by air quietly overstates heat removal. Our five-step thermal boundary condition guide starts from the dominant resistance for that reason.

 

Generation and convection change the answer

 

Internal generation, such as electrical heating in a conductor, adds a source term. The profile is no longer linear, and local heat flux changes through the thickness. With constant k, the equation takes the Poisson form noted above. Convection adds a finite resistance at the surface, which contributes to the temperature drop between solid and fluid. Both are terms in the steady energy balance, so they alter the balance and boundary treatment rather than being dropped by default, as the Florida notes describe.

 

A practical rule: if the part dissipates power internally, keep the generation term. Electronics are the usual case, and our electronics thermal design guide shows where it enters.

 

When one dimension is not enough

 

The closed-form results assume heat moves in one direction. Textbooks such as Springer’s Heat Conduction treat one-dimensional, two-dimensional and numerical steady conduction as separate topics for a reason. Move to a multidimensional model when:

 

  • A small heat source sits on a larger plate, so heat spreads sideways.

  • Fins, corners, penetrations or edges dominate.

  • Materials with very different conductivities meet in a non-planar way.

  • Properties vary strongly with temperature.

 

A sound habit is to bound the problem by hand first, then use the numerical model to refine it. If your hand number and the model disagree by a wide margin, one of the boundary conditions is usually wrong.

 

Steady state thermal analysis with numerical methods

 

Numerical solvers discretize the domain and solve the steady equation on a mesh. Nellis and Klein list finite differences, matrix decomposition and Gauss–Seidel iteration among the methods. Nonlinear cases, with temperature-dependent properties, are solved iteratively. A NASA report on a steady-state thermal finite-element code for cooled structures describes Newton–Raphson iteration for this purpose.

 

The workflow in the Marquette thermal analysis tutorial is typical:

 

  1. Define the material conductivity.

  2. Apply temperature boundary conditions.

  3. Select heat-transfer elements and mesh the model.

  4. Run a data check, then solve.

  5. Inspect nodal temperature contours and path plots.

 

Check results against a one-dimensional estimate and an energy balance: heat in should equal heat out at steady state. For board-level work, see our PCB thermal analysis workflow. When a fluid and a solid exchange heat, the conjugate heat transfer guide covers coupling them.

 

Doing it in the Jewlz toolkit

 

The Jewlz Engineering Toolkit is a downloadable Excel-based tool for conduction, convection and radiation analysis. It supports variable material properties, a wide temperature range, multiple heat transfer modes and a built-in property database. That means the temperature-dependent conductivity discussed above does not require you to hunt for tables. Some of our engineering software is free, which suits students and small teams. You can see the full set on the Engineering Toolkit page, or start with the thermal analysis tools.


Jewlztech

Our perspective

 

Steady state is where every thermal model should begin. Before a mesh, before a solver, write down the resistances. Most of the time the answer tells you which one dominates, and that decides where your effort goes.   We built our toolkit around that habit. Conduction, convection and radiation sit in one place with a property database, so a first estimate does not stall on missing data or a license you do not have. Students can learn the physics with the same tool a working engineer uses to check a design.   Our aim is simple: professional-grade thermal and CFD analysis should not depend on a large software budget. Start with the resistance network, then let the toolkit carry the arithmetic and the temperature dependence.   Joel

 

FAQ

 

What is the difference between steady and unsteady heat transfer?

 

In steady heat transfer, temperatures are independent of time. In unsteady (transient) heat transfer, temperatures change with time and you need an initial temperature distribution to solve the problem. Steady cases need only boundary conditions.

 

Does steady state mean no heat flow?

 

No. Heat keeps flowing; what stops is the change in temperature. The heat entering any region equals the heat leaving it, plus any internal generation, so nothing accumulates.

 

Which equation do I use for steady heat conduction?

 

For constant conductivity and no generation, use Laplace’s equation, ∇²T = 0, which gives the resistance formulas for walls, cylinders and spheres. With generation, use ∇²T + q̇/k = 0. For variable conductivity, use the general form ∇·(k∇T) + q̇ = 0, usually solved numerically.

 

How many boundary conditions do I need?

 

Enough to give a unique temperature field: typically one condition on each boundary, such as a fixed temperature, a prescribed flux or convection with h and ambient temperature. No initial condition is needed at steady state.

 

Sources

 