Heat conduction in a cylinder differs from a flat wall in one way: the area the heat crosses grows with radius. That one fact gives you a logarithmic temperature profile, a log-based thermal resistance and a heat rate that stays constant while the heat flux falls. This article walks through those results, a numerical example, the heat-generation and transient cases, and the assumptions to check. If you would rather not redo the algebra by hand for every pipe, our Excel-based Jewlz Engineering Toolkit combines conduction, convection and radiation with a built-in material property database.
TL;DR
For a long hollow cylinder with fixed wall temperatures, heat flows radially and the problem is one-dimensional: T = T®.
Steady heat rate: Q = 2πkLΔT / ln(r2/r1). Thermal resistance: R = ln(r2/r1) / (2πkL).
Q is constant across the wall, but flux falls as 1/r because the area 2πrL grows.
With internal heat generation in a solid cylinder, the centerline is hotter than the surface by q̇r0²/(4k).
Transient problems add thermal diffusivity and an initial condition, and lead to Bessel-function solutions.
Table of Contents
When heat flow in a cylinder is one-dimensional and radial
Take a long hot-water pipe with the fluid temperature inside and outside held constant. Heat moves through the wall in the radial direction, and there is no significant transfer in other directions. Çengel’s heat transfer text notes that this lets you treat the problem as steady and one-dimensional, with temperature depending only on radius and not on the angle around the pipe or the distance along it. Long pipes and cylindrical containers approximate this well in practice.
The conditions that make the model valid:
The cylinder is long compared with its diameter, so end effects are negligible.
Inner and outer surface temperatures (or fluid conditions) are uniform around the circumference and along the length.
The material is homogeneous, and for the simple closed-form results, conductivity k is constant.
For the basic formula, there is no internal heat generation.
When these hold, you can drop the angle and axial terms from the general cylindrical heat equation and solve an ordinary differential equation in r.
Why the profile is logarithmic, not linear
In a flat wall the area is the same at every depth, so the steady temperature profile is a straight line. In a cylinder the area at radius r is A = 2πrL. Fourier’s law says the flux is q = −k dT/dr. At steady state the same heat rate Q must cross every concentric shell, so the flux has to fall as Q/(2πrL).
Subramanian’s Clarkson University notes make this point: because flux varies as 1/r, the gradient dT/dr must vary too, and the temperature becomes logarithmic in r for constant k. Baehr and Stephan summarize the family: a plate is linear, a hollow cylinder logarithmic, a hollow sphere hyperbolic.

The practical consequence: the temperature drops faster near the inner surface, where the area is small and the flux is highest, and more slowly near the outer surface.
The formulas you need
For a hollow cylinder with inner radius r1 at temperature T1, outer radius r2 at T2, length L and constant conductivity k, no generation, the governing equation (1/r) d/dr (k r dT/dr) = 0 gives the results below, as presented in the NTU Chapter 3 notes.
Quantity | Expression | Units |
Temperature profile | T® = (T1 − T2) · ln(r/r2) / ln(r1/r2) + T2 | K or °C |
Heat rate | Q = 2πkL(T1 − T2) / ln(r2/r1) | W |
Thermal resistance | R = ln(r2/r1) / (2πkL) | K/W |
Flux at radius r | q″ = Q / (2πrL) | W/m² |
The heat rate then follows the electrical analogy, Q = (T1 − T2)/R, which is what lets you add the cylindrical resistance in series with convection resistances on the inside and outside of an insulated pipe.
The NTU notes also stress that the heat rate, not the heat flux, is constant in the radial direction, because the area 2πrL increases with radius. A common mistake is to treat the flux as constant and compute it at the wrong radius.
The log-mean area shortcut
If you prefer the flat-wall form Q = kAm ΔT / (r2 − r1), Baehr and Stephan show the correct area is the logarithmic mean, Am = (A2 − A1) / ln(A2/A1). A plate uses the arithmetic mean and a sphere the geometric mean. For thin walls the log mean is close to the arithmetic mean, which is why the flat-wall approximation works for thin-walled tubes and degrades as the wall thickens.
Worked example: a steel pipe wall
Take a 10 m run of carbon steel pipe, k = 45 W/m·K, with inner radius 0.050 m and outer radius 0.060 m. The inner wall is at 150 °C and the outer wall at 140 °C.
Step 1: the log term. ln(0.060/0.050) = ln(1.2) = 0.1823.
Step 2: resistance. R = 0.1823 / (2π × 45 × 10) = 0.1823 / 2827 ≈ 6.45 × 10⁻⁵ K/W.
Step 3: heat rate. Q = ΔT / R = 10 / 6.45 × 10⁻⁵ ≈ 155,000 W, or about 155 kW through the wall (this is a bare conduction number with surface temperatures fixed, so it is large by design).
Step 4: flux at each surface.
Inner: 155,000 / (2π × 0.050 × 10) ≈ 49,400 W/m²
Outer: 155,000 / (2π × 0.060 × 10) ≈ 41,100 W/m²
The ratio is 1.2, exactly r2/r1, which is a quick sanity check for your own calculations.
Step 5: mid-wall temperature. At r = 0.055 m, T = 150 − 10 × ln(0.055/0.050) / 0.1823 = 150 − 5.23 ≈ 144.8 °C. A linear profile would give 145.0 °C. The gap is small here because the wall is thin. For thick walls it grows, and our guide on thick wall cylinder temperature goes from the log formula to numerical validation.
In real systems you rarely know the wall temperatures. You know the fluid temperatures and heat transfer coefficients, so the series resistance (inside convection, wall conduction, insulation, outside convection) becomes the working model. Our insulated pipe heat loss example shows that workflow, and the heat conduction calculation guide covers the wider set of formulas.
Solid cylinder with internal heat generation
Fuel rods, electrical conductors and cylindrical cells generate heat inside the material. For a solid cylinder of radius r0 with uniform generation q̇ (W/m³), surface temperature Ts and symmetry at the center, the BUET ME307 lecture notes give:
T® = Ts + (q̇ r0² / 4k)(1 − r²/r0²)
Centerline maximum: T0 = Ts + q̇ r0² / (4k)
With convection to fluid at T∞: Ts = T∞ + q̇ r0 / (2h)
Example: a 10 mm radius rod, k = 15 W/m·K, generating 5 × 10⁶ W/m³, cooled by fluid at 25 °C with h = 100 W/m²·K.
Surface rise above the fluid: q̇ r0 / (2h) = 5 × 10⁶ × 0.01 / 200 = 250 K, so Ts = 275 °C.
Centerline rise above the surface: q̇ r0² / (4k) = 5 × 10⁶ × 10⁻⁴ / 60 ≈ 8.3 K, so T0 ≈ 283 °C.
The lesson is common in practice: here the convective film dominates the temperature rise, not conduction inside the rod. Check which resistance controls before refining the one that does not. The same thinking applies to battery energy storage systems, where cold plates and temperature alarms protect cells; see BESS thermal management design for one application of these principles.
Transient conduction in a cylinder
When temperatures change with time, the radial equation becomes ∂T/∂t = α(∂²T/∂r² + (1/r) ∂T/∂r), where α = k/(ρc) is thermal diffusivity. The University of Washington notes explain what you must add: a boundary condition (for example, a fixed surface temperature) and an initial condition (for example, a uniform starting temperature). The solution is a series of Bessel-function radial modes, each decaying exponentially in time, with eigenvalues set by the boundary condition.
You rarely need the full series for engineering work. If the Biot number is small, the cylinder stays nearly isothermal and a lumped model is enough. If it is not, check the Fourier number to decide whether one series term suffices. Our article on Bi ≤ 0.1 and Fo > 0.2 for transient conduction explains both criteria with examples.

Assumptions and errors to check
Before you trust a number, run through this list:
Is it long enough? The 1-D radial model neglects axial effects. For short cylinders or near end caps, the heat flow is two-dimensional.
Is k really constant? Metals and insulation change conductivity with temperature. Across a wide span, use a mean k at the average wall temperature or a variable-property model.
Radius or diameter? The resistance in terms of diameters, ln(d2/d1), is identical to the radius form, but mixing the two inside one log is a frequent slip. Only the ratio matters, so just keep units consistent.
Natural log. The formulas use ln, not log10. Using log10 understates resistance by a factor of about 2.3.
Constant flux assumption. Q is constant, not q″. Report flux with its radius.
Contact resistance. Layered walls with imperfect contact add resistance the ideal formula omits.
Boundary conditions. Fixed wall temperatures are an idealization. Convection and radiation at the surfaces usually set the real temperatures.
When the geometry or the physics goes beyond these assumptions, such as fluid flow coupled to a solid wall, move to a conjugate heat transfer approach, and see our heat transfer model guide for choosing between analytical, lumped and numerical methods.
Doing this faster with the Jewlz Engineering Toolkit
Hand calculation is ideal for a single check. It gets tedious when you sweep radii, swap materials or combine conduction with convection and radiation across a wide temperature range. Jewlz Engineering Toolkit is a downloadable Excel-based tool that handles conduction, convection and radiation analysis, supports variable material properties and includes a built-in property database. We also offer free engineering software for basic thermal work, so students and small teams can run professional-grade thermal and CFD analyses without paid licenses.
Start with the Jewlz Engineering Toolkit for thermal analysis and heat transfer, or explore the thermal analysis tools.

If your problem also involves flow around or inside the cylinder, our CFD simulation tools cover the fluid side, and the guide on mapping governing equations to solver setup shows how the conduction terms above appear in a solver.
Our perspective
Most errors we see in cylindrical conduction problems are not calculus errors. They are bookkeeping errors: the wrong radius for the flux, a constant k where the temperature range is wide, or a convective film that nobody checked. That is why we built our toolkit around a single workflow: conduction, convection and radiation in one place, with variable material properties and a built-in property database. You should be able to move from the log formula to a realistic wall, insulation and surface model without switching tools. We also believe the basic tools should be free. Students learning the logarithmic profile and small teams sizing a pipe should not need a license before they can check a result. When you need the advanced toolkit, it is a monthly subscription to the Thermalysis Toolkit. Joel
FAQ
Why is the temperature profile in a cylinder logarithmic?
The area for heat flow, 2πrL, increases with radius. With the same heat rate crossing every shell, flux falls as 1/r, so the gradient is steeper near the inner surface. Integrating Fourier’s law with that area gives a logarithmic profile for constant conductivity.
What is the thermal resistance of a hollow cylinder?
R = ln(r2/r1) / (2πkL), in K/W, where r1 and r2 are the inner and outer radii, k is conductivity and L is length. Divide the temperature difference by R to get the heat rate. It adds in series with convection resistances for pipes with fluids inside and outside.
Is the heat flux constant through a cylindrical wall?
No. The heat rate Q is constant at steady state, but the flux q″ = Q/(2πrL) is higher at the inner surface and lower at the outer one. In the worked example above, the ratio of inner to outer flux equals r2/r1.
Where is the maximum temperature in a solid cylinder with heat generation?
At the centerline. For uniform generation q̇ and surface temperature Ts, T0 = Ts + q̇ r0² / (4k). With convection, the surface temperature itself is Ts = T∞ + q̇ r0 / (2h).
When can I treat a cylinder as one-dimensional?
When it is long relative to its diameter, boundary conditions are uniform around the circumference and along the length, and end effects are negligible. Then temperature depends on radius only.
Sources
Recommended


Comments